CS-XU10ZKH-1 (1.0HP-2.5HP) X-Premium Inverter R32 XU Series (ZKH-1) CS/CU-XU10ZKH
- nanoe™ X 24-hour protection inhibits various pollutants and deodorises odours
- Inside Cleaning On Demand ensures the inside of the indoor unit is pollutant-free
- Manage your air conditioner using your mobile device with Comfort Cloud App
- Advanced humidity control operated by Dry Mode and iAUTO-X with built-in Humidity Sensor
- 15 meters long air distance with AEROWINGS
- Energy efficiency with ECO Mode with A.I. Control, Inverter and environmentally friendly R32 refrigerant
Clean and Fresh Environment Every Day
New nanoe X Generator Mark 3*:
Equipped with the latest nanoe X Generator Mark 3 to offer greater effectiveness in inhibiting various pollutants and deodorising odours at a faster pace compared to the previous nanoe X Generator Mark 2.
*The content of this page is specific to residents of Malaysia.
*Testing organisation: Shokukanken, Inc. Test subject: Adhered MS2 Phage Virus. Test volume: Approx. 25m³ laboratory. Test result: Inhibited 99.99% in 2 hours.
Test Report No.: 227131N
Inside Cleaning On Demand:
The newly improved inside cleaning function can be activated on a need basis. It works inside of an indoor unit to remove moisture, and release nanoe™ X particles, inhibiting various pollutants while ensuring that the inside of the indoor unit is always dry and clean.
Effective in Removing 99% of Dust Particles:
Effective in removing 99% of dust particles*, nanoe-G releases negative ions to capture dust particles as small as PM2.5, carrying them back to the filter to provide a cleaner indoor environment.
*Testing organisation: FCG Research Institute, Inc. Testing method: nanoe-G-equipped air conditioner was operated and tested in a 23m³ sized test room.
Test result: Removed 99% of particles in 202 minutes (compared to the initial concentration). (25034) Not a result of experiments in an actual use environment. Results may vary based on usage, and seasonal and environmental variables (temperature and humidity).
Connect & Control Your Air Conditioners Anywhere, Anytime:
With the built-in Wi-Fi and Panasonic Comfort Cloud App, connect and control multiple air conditioning units from anywhere, at home or away.
Better Living, Together with Energy-saving and Eco-friendly Technologies:
Inverter technology helps to save on energy bills without compromising comfort, reducing energy consumption significantly compared to non-Inverter. Panasonic’s Inverter technology uses a micro-computer with compressor to precisely control temperature, providing a comfortable environment while saving energy.
Intelligently Balances Energy Savings and Comfort:
Every space has a different temperature and it varies throughout the day. ECO Mode with Artificial Intelligence (A.I.) Control learns and judges the optimal ECO level to maximise energy savings up to 20%* while providing consistent cooling comfort.
*Comparison of ECO mode & normal mode by using 1.5HP Inverter Model.
Humidity Control for Better Comfort:
Humidity Sensor Optimises an Ideal Indoor Environment
iAUTO-X together with built-in Humidity Sensor constantly monitors and adjusts relative humidity levels to below 60% for an optimal indoor environment, so you can enjoy comfortable cooling all day long.
Remove Excess Moisture with Dry Mode and Humidity Sensor:
Dry Mode together with built-in Humidity Sensor accurately detects and adjusts the humidity level in the room to below 55%, removing excess moisture to maintain the comfort level of its occupants.
Faster Cooling with iAUTO-X:
iAUTO-X provides 25%* faster cooling through the use of Panasonic Thermal Enhancement Technology (P-TECh) which enables the compressor to achieve maximum frequency quickly from start-up, allowing you to relish the cooling comfort instantly, even on a scorching hot day. This feature can also be reactivated whenever the room is getting warmer due to the increase of occupants in it, keeping everyone comfortable at all times.
Basic Specification | Model | Indoor (50 Hz) | CS-XU10ZKH-1 | CS-XU13ZKH-1 | CS-XU18ZKH-1 | CS-XU24ZKH-1 |
Outdoor | CU-XU10ZKH-1 | CU-XU13ZKH-1 | CU-XU18ZKH-1 | CU-XU24ZKH-1 | ||
Cooling Capacity (min-max) (kW) | 2.80 (0.92-3.60) kW | 3.66 (1.02-4.20) kW | 5.57 (1.10-6.21) kW | 6.60 (1.12-7.18) kW | ||
Cooling Capacity (min-max) (Btu/h) | 9,550 (3,140-12,300) Btu/h | 12,500 (3,480-14,300) Btu/h | 19,000 (3,750-21,200) Btu/h | 22,500 (3,820-24,500) Btu/h | ||
EER (min-max) (Btu/hW) | 13.64 (13.96-11.28) Btu/hW | 13.16 (13.92-12.12) Btu/hW | 13.01 (13.89-12.47) Btu/hW | 12.23 (12.32-11.95) Btu/hW | ||
EER (min-max) (W/W) | 4.00 (4.09-3.30) W/W | 3.85 (4.08-3.56) W/W | 3.82 (4.07-3.65) W/W | 3.59 (3.61-3.50) W/W | ||
CSPF (W/W) | 6.45 W/W | 6.43 W/W | 7.09 W/W | 6.21 W/W | ||
Electrical Data | Voltage | 230 V | 230 V | 230 V | 230 V | |
Current | 3.3 A | 4.2 A | 6.5 A | 8.3 A | ||
Power Input (min-max) | 700 (225-1,090) W | 950 (250-1,180) W | 1,460 (270-1,700) W | 1,840 (310-2,050) W | ||
Moisture Removal (L/h) | 1.6 L/h | 2.1 L/h | 3.0 L/h | 3.7 L/h | ||
Moisture Removal (Pt/h) | 3.4 Pt/h | 4.4 Pt/h | 6.3 Pt/h | 7.8 Pt/h | ||
Air Circulation | Indoor | 11.8 m³/min (415 ft³/min) | 12.5 m³/min (440 ft³/min) | 18.7 m³/min (660 ft³/min) | 19.2 m³/min (680 ft³/min) | |
Outdoor | 27.6 m³/min (970 ft³/min) | 30.9 m³/min (1,090 ft³/min) | 34.9 m³/min (1,230 ft³/min) | 34.9 m³/min (1,230 ft³/min) | ||
Noise Level | Indoor (H / L / Q-Lo) | 38/26/19 dB(A) | 40/28/19 dB(A) | 44/32/27 dB(A) | 45/34/28 dB(A) | |
Outdoor (H) | 47 dB(A) | 48 dB(A) | 50 dB(A) | 52 dB(A) | ||
Dimensions (Indoor) | Height | 295 mm | 295 mm | 295 mm | 295 mm | |
Width | 870 mm | 870 mm | 1,040 mm | 1,040 mm | ||
Depth | 229 mm | 229 mm | 244 mm | 244 mm | ||
Dimensions (Outdoor) | Height | 511 mm | 542 mm | 619 mm | 619 mm | |
Width | 650 mm | 780 mm | 824 mm | 824 mm | ||
Depth | 230 mm | 289 mm | 299 mm | 299 mm | ||
Net Weight | Indoor | 10 kg (22 lb) | 10 kg (22 lb) | 12 kg (26 lb) | 12 kg (26 lb) | |
Outdoor | 17 kg (37 lb) | 22 kg (49 lb) | 30 kg (66 lb) | 31 kg (68 lb) | ||
Refrigerant Pipe Diameter | Liquid Side | ø 6.35 mm (1/4 inch) | ø 6.35 mm (1/4 inch) | ø 6.35 mm (1/4 inch) | ø 6.35 mm (1/4 inch) | |
Gas Side | ø 9.52 mm (3/8 inch) | ø 9.52 mm (3/8 inch) | ø 12.70 mm (1/2 inch) | ø 12.70 mm (1/2 inch) | ||
Pipe Extension | Chargeless Pipe Length | 7.5 m | 7.5 m | 10 m | 10 m | |
Maximum Pipe Length | 20 m | 20 m | 30 m | 30 m | ||
Maximum Elevation Length | 15 m | 15 m | 20 m | 20 m | ||
Additional Refrigerant Gas* | 10 g/m | 10 g/m | 15 g/m | 15 g/m | ||
Power Supply | Indoor | Indoor | Indoor | Indoor | ||
Comfort Features | iAUTO-X | Yes | Yes | Yes | Yes | |
iAUTO-X with Humidity Sensor | Yes | Yes | Yes | Yes | ||
Dry Mode with Humidity Sensor | Yes | Yes | Yes | Yes | ||
ECO Mode With A.I. | Yes | Yes | Yes | Yes | ||
Inverter Control | Yes | Yes | Yes | Yes | ||
Sleep Mode | Yes | Yes | Yes | Yes | ||
Quiet Mode | Yes | Yes | Yes | Yes | ||
Soft Dry Operation Mode | Yes | Yes | Yes | Yes | ||
Personal Airflow Creation | Yes | Yes | Yes | Yes | ||
Cleaner Air Features | nanoe™ X | Yes (Generator Mark 3) | Yes (Generator Mark 3) | Yes (Generator Mark 3) | Yes (Generator Mark 3) | |
Inside Cleaning On Demand | Yes | Yes | Yes | Yes | ||
nanoe-G | Yes | Yes | Yes | Yes | ||
Odour Removing Function | Yes | Yes | Yes | Yes | ||
Removable Washable Panel | Yes | Yes | Yes | Yes | ||
Convenience Features | 24-Hour Dual ON & OFF Real Setting Timer | Yes | Yes | Yes | Yes | |
LCD Wireless Remote Control | Yes | Yes | Yes | Yes | ||
Wireless LAN Remote Control (For Internet Connection) | Yes (Built-in) | Yes (Built-in) | Yes (Built-in) | Yes (Built-in) | ||
Wired Remote Control | Yes (Optional) | Yes (Optional) | Yes (Optional) | Yes (Optional) | ||
Reliability Features | Random Auto Restart | Yes (32 Restart Patterns) | Yes (32 Restart Patterns) | Yes (32 Restart Patterns) | Yes (32 Restart Patterns) | |
Blue Fin Condenser | Yes | Yes | Yes | Yes | ||
Long Piping (max.) | 20 m | 20 m | 30 m | 30 m | ||
Top Panel Maintenance Access | Yes | Yes | Yes | Yes | ||
Self-Diagnostic Function | Yes | Yes | Yes | Yes | ||
Note | *When pipes are not extended from the chargeless pipe length, the required amount of refrigerant is already in the unit. | *When pipes are not extended from the chargeless pipe length, the required amount of refrigerant is already in the unit. | *When pipes are not extended from the chargeless pipe length, the required amount of refrigerant is already in the unit. | *When pipes are not extended from the chargeless pipe length, the required amount of refrigerant is already in the unit. | ||
Note | Please read the Installation Instructions carefully before installing the unit, and the Operating Instructions before using it. Specifications are subject to change without prior notice. | Please read the Installation Instructions carefully before installing the unit, and the Operating Instructions before using it. Specifications are subject to change without prior notice. | Please read the Installation Instructions carefully before installing the unit, and the Operating Instructions before using it. Specifications are subject to change without prior notice. | Please read the Installation Instructions carefully before installing the unit, and the Operating Instructions before using it. Specifications are subject to change without prior notice. |