F-M15H5 Ceiling Fan F-M15H5 (60 Inch) Econavi F-M15H5VBSRH - Long
- 5-Blade Design
- ECONAVI Features
- Yuragi Function
- LCD Remote Control
- Enhanced safety Features
- 3-preset Speed Selection
- 9-sequential speed selection
- 1 - 8 Hour Off Timer
- 2 - 8 Hour Sleep Timer
Cool & Comfortable, Always
Ceiling fans create a strong airflow and also aid the circulation of cool air from air conditioning systems. Panasonic Ceiling Fans combine innovative technology with beauty contemporary designs.
• ECONAVI feature
• DC Motor Technology
• Yuragi function
• Enhanced safety features
• LCD remote control
• 9-sequential speed selection
• Durable blades (PPG Material)
• 1 - 8 hour off timer
• 2 - 8 hour sleep timer
• Sleek and smooth design
ECONAVI, Temperature Sensor, DC Motor
1) ECONAVI Integrated Circuit
This intelligent microprocessor analyzes information from the sensor and adjusts the fan speed to optimum conditions.
2) Temperature Sensor
Detects surrounding temperature.
3) DC Motor
How it works?
As for DC (Direct Current) motor, the direct (AC) power source will be connected to a transformer which converts the power to DC. The effect will decrease the amount of power used by a direct current instead of alternating current. The motor's rotor will then be rotated by using a system of magnets of opposing polarity where this process requires less electrical energy.
Advantages of a DC motor:
1. Uses less energy - up to 55% compared AC motor
2. Quiet operation
3. More compact and lighter motor
ECONAVI - How It works?
Senses
ECONAVI features Intelligent surrounding temperature detection that senses every 3 minutes.
Self Adjusts
ECONAVI feature will adjust speed automatically to give the most comfortable air to human body according to the surrounding temperature and room conditions.
Saves
ECONAVI with smart eco sensor now has the abilities to detect and reduce energy waste. You can now enjoy more saving of up to 64%*.
Comfortable - 1/f Yuragi* (Natural Breeze)
These fans are equipped with 1/f Yuragi function which is a fluctuating pattern to generate a gentle breeze. By this sophisticated formula, in varying air velocity and controlling wind force, these new ceiling fans gives you a peaceful and comfortable feeling.
Current function : rhythm breeze
This regulator pattern decreases the body temperature after a period of time. Thereafter, you may feel anxious and uncomfortable when the wind velocity changes.
New Function : 1/f Yuragi
Incorporated with this human-concerned technology, this kind of rhythm maintains your external body temperature by giving you a feeling of natural wind when there is a change of wind velocity.
Excellent - 3D BLADE (Powerful Airflow)
With the exclusive and unique 3D blade design, it provides a smooth and strong air flow while maintaining operating noise in low level.
LCD Remote Controller
All functions can be operated by simply using the LCD remote controller. With clear speed selection, timer indication and mode selection displayed at the LCD panel, it provides greate convenience and ease for you to operate.
On/Off Button
Press On/Off Button to activate or deactivate the ceiling fan
Yuragi Button
One touch button for natural breeze
Timer select Button
Press to select timer. On timer Off timer Release
Speed Button
From slow speed to cooling in 9 speed selection
Sleep mode Button
Gradually reduce fan speed according to the time setting
Time set Button
Press to set time
Auto mode Button
Press to set or release auto mode
Caring - Sleep Mode
These fan are equipped with Sleep Mode, by which fan speed and timer will gradually reduce until the fan is off. This function not only creates an optimal sleeping environment but also enhances energy saving as well.
* Note:
Sleep mode is disabled at speed 1 and 1 hour setting.
Operation patter will be different subject to different model and setting, please refer to the operation instruction for details.
Safety Policy by Panasonic
Preventive Measures For Safety
Panasonic aims to minimize and reduce accidents to occur. Thus, Panasonic practices safety policy to prevent any dangerous mishaps.
To pursue a higher quality of life, ceiling fans are expected to have more functions and value added features. However, it is also crucial to consider the safety and reliability features of the fan when you select a ceiling fan.
Cut-off Safety Switch
Problem
If there is any damage at either the shaft or the bolt due to improper installation, abnormal wobbling from fan will occur when it operates. The damage will cause the shaft or the bolt to break if the fan continues to operate.
Preventive Measures
When there is excessive wobbling, the safety cut-off switch will be triggered and power supply will be cut off. The cut-off switch works by detaching the lever from the switch and the fan will stop.
If Motor stops
Stop using immediately and seek contact for qualified installers or authorized Panasonic service dealers for assistance.
Safety Blade Hook
Problem
The fan blade may detach from the fan motor should there be improper installation coupled with the fan blade wearing off, deformed blade shape or stronger wind blowing to the fan.
Preventive Measures
The broken blade will be visibly hanging with the aid of safety blade hook when the fan is functioning (as shown in the picture) as an indication.
If Blade breaks
Stop using immediately and seek contact for qualified installers or authorized Panasonic service dealers for assistance.
Safety Wire
Problem
Due to improper installation or should malfunction occur, the fan motor may detached from the pipe rod due to factors such as wearing of shaft bolt, etc.
Preventive Measures
The safety wire helps to secure the fan motor with the ceiling hook to prevent the motor from falling when the fan motor detaches from the pipe rod.
If need shorter/longer pipe
Contact qualified installers or authorized Panasonic service dealers for assistance.
Use the original pipe rod
Original pipe rod comes with the safety wire and safety cut-off switch in line with Panasonic safety policy. Also, do ensure the pipe rod is fully tightened to the motor shaft. (Bolt tightening torque is 800 – 1200 N.com)
Wobbling Reduction Mechanism
Problem
Constant wobbling will cause the bolt, motor shaft and pipe rod to wear off which may cause breakage or falling of the fan to happen should the condition worsened.
Preventive Measures
The newly developed anti-wobbling structure helps to reduce wobbling between bolt, motor shaft and pipe rod. It can minimize the parts from wearing off and prevents from detaching the fan.
-
ECONAVI / DC Motor
Saving of up to 64%* / 55% -
Dimension:
Short pipe (QP1) Width: 1500mm (60"), Height: 290mm\nLong pipe (RP1) Width: 1500mm (60"), Height: 367mm -
Colour
Platinum Silver
Fan Size (inch/cm) | 60”/150cm | |
---|---|---|
Power Consumption (W) | (Low) | 3 |
(High) | 41 | |
Fan Speed (RPM) | (Low) | 80 |
(High) | 235 | |
Air Velocity (m/min) (Low) |
210 | |
Air Delivery (m³/min) | 245 | |
Motor HP | 0.1 | |
Motor Type | 14 Pole Condenser | |
Noise Level (dB) | 54 | |
Nett Weight (kg) | 5.3 | |
Length from pully to PCB cover (mm) | 290 | |
Length from pully to blade (mm) | 210 | |
Colour | Platinum Silver |